If the stoveâs fire dances lazily and the flames have black tips, the fire isnât burning efficiently. Greasing the Auger Bearing on 25-PDVC/ 25-PDV, Replacing the Auger Bearing to Improve Safety, Maintain Auger Motor & Reduce Auger Jams, Tutorial: How to Reverse the Direction of an Auger Motor. 1. The heat expansion differs for those two materials which causes a leak and the part fails. The hose and bladder membrane are connected to either metal or plastic. The stove also uses a thermostat. To resolve this issue, the damper needs to be adjusted in the air intake on back of the stove. Our heavy duty metal vacuum switch may be ordered here. The wires can be pulled off the vacuum switch and connected together. If this is the case, it should be replaced as soon as possible. The exhaust blower works effectively when the tube is installed vertically. If the vacuum hose and ports are clean then it is most likely the vacuum switch. It also can indicate a bad door gasket or a bad ash pan gasket if there is one on the stove. Unfortunately the vacuum hose employed in pellet stoves still vary greatly today.
y’all are terrific! Usually, this system indicates a bad combustion (exhaust blower) or venting plugged with ash or a dirty stove. This safety system employs a hose and a vacuum switch. ¥ Auger Motor (Insert & Stove) ¥ Convection Blower ¥ Exhaust Fan Gasket ¥ Combustion Blower ¥ Two Insert Exhaust Tube Gaskets Bring along the following items as well: ¥ Door & Glass Gasket ¥ Igniter ¥ Flow Switch 3 Bags of high quality pellets Many pellet stove problems are due to poor quality pellets. Get it as soon as Mon, Feb 22. There is a lot to love about this pellet stove, including just how quiet it operates. If the exhaust blower does not work when hotwired, or if it pushes little air, replace. How to Adjust the Air Intake for a Pellet Stove. I will check the voltage and respond back. If no fuses have blown on the control box, the control box may need to be replaced. Have stopped using the stove⦠The higher auger motor current is switched by a triac on these electronic control panels. Required fields are marked *. Replacement exhaust/combustion blower for Lopi / Avalon pellet stoves and inserts. The exhaust fan can not keep up with the smoke. Quadra-Fire Help & Troubleshooting > Uncategorized > Troubleshooting > Troubleshooting for Classic Bay 1200, Castile, Contour, MT Vernon, & Santa Fe model pellet stoves > Troubleshooting the Exhaust Blower, Author: Amyb
(Thin wall hose pinches, yellows and cracks), East Coast Hearth, 2017. You can also bench test the motor and watch it spin, if it’s weak or slow to start it needs to be replaced. You’ll also want to check the combustion motor, you can check the voltage going into it – should be 115V on high. Thick Wall High Temperature Hi Performance Vacuum Hose, Green Mountain Grills - Pellet Grill Parts, Magnum & Country Flame Pellet Stove Parts, Pelpro/Glow Boy/Cheap Charlie/Pleasant Hearth Pellet Stove Parts, Breckwell & Golden Eagle Pellet Stove Parts, Enviro & Vistaflame & Bosca Pellet Stove Parts, Parts for Quadra-Fire & Heatilator Stoves, Parts for PE Warmland & True North Pellet Stoves. 00. You lead me to the real problem. Have stopped using the stove. 2. If the wiring all checks out, you will need to check for power coming into the stove and from the control box to the blower. I consider Mt View my go-to site for my stove needs. Take a look at the door seal and make sure it closes with a perfect fit to eliminate air leaks. The hopper is empty. Thanks. PelletStovePro - King Ashley 5502 Pellet Stove Distribution Convection Blower Fan 80472A. If there is an air leak from the stove door or the ash pan seal, this can cause a shortage of air to the flame. A-E-027 - PP7610. Make sure that the stove power is disconnected and neither of the vacuum switch connectors touch the chassis or ground. 2. Begin by confirming that the blower is properly connected to the wire harness. 2. I would start by inspecting the stove wiring between the control box and the exhaust blower. A combustion blower sucks air into the stove through an air vent and discharges smoke through an exhaust vent. Recently, I have come across a lot of cases where pellet stoves shut down prematurely after 3 to 6 hours or right after the start cycle when the fire lights up.Most of these intermittent problems are due to aging parts in the automatic exhaust blower vacuum sensing safety shutdown. 1.The metering auger will stop feeding pellets, but the push auger stays running. If a pellet stoveâs fire is smokey upon start-up, or if it puffs smoke, clean the firepot. Pellet Stove Parts, Accessories, and Hearth Supplies. The heat from the pellet stove is delivered according to the settings on the thermostat setting. Speed test in the wood pellet stove Install the exhaust blower into stove with a testing jumper for connection to a digital voltage meter. 6 Comments, Troubleshooting for Classic Bay 1200, Castile, Contour, MT Vernon, & Santa Fe model pellet stoves, Castile, CB1200, Mt Vernon, quadra-fire mainenance, Quadrafire, quadrafire combustion blower, quadrafire draft motor, quadrafire exhaust blower, quadrafire help, quadrafire troubleshooting, Santa Fe. Five star support. With an efficiency rate of 86%, this product will be ideal for your pick. Comfortbilt Pellet Stove HP22. Recently, I have come across a lot of cases where pellet stoves shut down prematurely after 3 to 6 hours or right after the start cycle when the fire lights up. Did you know⦠Most people remove ash from their stove ⦠July 31, 2017
Help. I have also seen the vacuum switch with the hose on the wrong port or the wires not connected to the correct connectors. 00. Most of these intermittent problems are due to aging parts in the automatic exhaust blower vacuum sensing safety shutdown. Why is my pellet stove so loud? You can check the timing for the auger feed. Remove the burn pot and clean it thoroughly. Some of the more flexible silicone like the one in the picture below is tight fitting but thin wall and can yellow and crack easier. With the new exhaust and board, the stove works great. when feed auger is off it runs normal. This is either an issue with the control board or the exhaust fan. Quadrafire Mt Vernon Pellet Stove Exhaust Combustion Blower SRV7000-193 - 10-1111 G at Pelletstovepro.net - online replacement parts seller for your pellet stove, gas fireplace in California. You may have a loose connection or a broken wire somewhere. Closed circuit voltage will read: 115v on high, 85v on medium, and 75v on low.) Quadra fire Classic bay 1200 Exhaust Blower slows down when feed auger kick on. A vacuum error can occur if an upgraded high speed blower is installed in a Magnum BabyCountryside stove. Press the STOP button on the control panel. Ensure the blower is wired properly, and that all wire pins are connected securely and test for broken wires. Loose wires can cut power to the motor ⦠$10.30 $ 10. If the motor is very noisy it is probably going bad. Check for power at the blue wire on the Molex connector with a volt meter (open circuit voltage should read 115v on high, medium and low. Pellet Stove Parts - Augers and Auger Motors, How to Easily Replace / Install an Auger Motor in your Pellet Stove- Tutorial. See pic 8 in for test setup. However, this would cause immediate failure. Likewise, a dirty vent or stove may restrict airflow, causing the stove to run for a very long time as it tries to cool down. Printed 3/18/98 Travis Industries Pellet Stove Troubleshooting Guide (© 1994) If your pellet stove fails to heat, this is actually a safety feature to prevent the pellet stove from overheating. Had a reserve board and installed it. If the blower is working, the stove has no mechanical problems. If the stove works there is a vacuum detection issue. Only 4 left in stock - order soon. In earlier stoves, metal vacuum switches with solid contacts switched the 120 vac going to the auger. Common causes for E-1 codes. Enviro Pellet Stoves: EF2 EF3 EF4 EF5 (Evolution) Empress FS Empress FPI Meridian Milan Mini Solus Windsor Enviro part# 50-901 Replaces part # EF4i-007, EF-007, EF5-114 50-473. A blower in top condition produces optimum combustion, completely burning ⦠If the encoder on your pellet stove is broken, you will not be in doubt as the pellet stove will immediately report an error and the pellet stove will begin to produce a high pitch sound due to the flue gas not running at the optimal speed. Under normal operating conditions, both the blower and the feed motor should be able to run at the same time without any problems. pellet stove convection blower shuts off, STOVE SHUTS OFF AND DISPLAYS WARNING CODE âEâ Possible Causes: Possible Remedies: (Unplug stove first when possible) 1. The stove will begin the shut-down process, which takes approximately 45 minutes. The vacuum hose is connected from the exhaust plenum to the negative port on the vacuum switch. Anyway I got home a couple days later and tested the stove out with no problems a couple of times â normal start up, normal turning on of vent fan and room fan etc. Do I need a chimney to install a pellet stove? They range from the more rubbery and flexible silicone to a harder plastic formulation. If no power is present at the blue wire, inspect the wire harness and control box. Great service, great on-site Q&A response. Breckwell Pellet Stove Combustion Exhaust Blower Fan Motor. Thanks. It then pulls the heated air across the heat exchanger and pushes the air and smoke up and out the flue venting. Thanks for your suggestions. Here are some vent-free stoves are ultra-convenient, 99% efficient and have a ⦠Your email address will not be published. Always check the above conditions before replacing parts What can go wrong with an older stove and why?Aging vacuum hoses get stiff, brittle and crack, and some get stretched where they connect to the hose barb. At East Coast Hearth we sell only the High Performance Thick wall high temperature flexible silicone hose for not only a tight fit but longer lasting too.Pic 1 - Shows Englander plastic vacuum switch, Enviro hybrid metal & plastic vacuum switch made by Honeywell and Magnum plastic vacuum switchPic 2 - Shows older heavier metal vacuum switch - These metal switches last many years.Pic 3 - Yellow arrow shows constriction in hose where it was routed under a hold down clamp in back of stove. Pat Nicholson See picture of an early 1990's Avalon Avanti Vacuum switch and vacuum hose below. Why choose a pellet stove without ventilation The pellet stoves without ventilation are stoves that can heat naturally, per natural convection, without any fan. If the air intake is adjustable, check to see that it's in the correct position and has not been accidentally moved. 4.1 out of 5 stars 29. We have an online form you can fill out to get help with your stove. With one of the largest viewing areas on the market, this stove is capable of heating just under 3000 square feet. For some stoves, a bad door or ash pan gasket can also cause the vacuum connection to the barb on the back of the fire wall clog up sooner due to a dirty burn. When it does this all the fans on the stove will shut off. What size vent pipe do I need for a pellet stove? Instead, ⦠Most pellet stoves use the negative port because the hose barb on the exhaust plenum is sucking air in and pulling the vacuum switch closed. Pellet Stove Fire Is Smokey. If you know what you need you can place your order on our secure website 24/7. The pellet stove also has an exhaust blower, which pushes gasses to the backside of the stove through a narrow pipe. In the case of Englander stoves with dual augers, the switch is only connected to the top auger which also stops the pellets from feeding and shuts the stove down. The air damper is open too much for the low feed setting. Use our handy parts diagrams to easily find the correct part for your model! How can I find the model or serial number on my pellet stove? Exhaust / combustion blower for Lopi and Avalon pellet stoves and inserts. If you need a recommendation for a reliable, stove tech, give us a call at 1-800-PELLETS. If this doesnât work, clean the firepot and the heat exchangerâs blower. 3. These metal vacuum switches were in series with the auger motor and had to carry the same current. FREE Shipping. When the unit gets cool the convection blower will shut off while the combustion 2. blower stays running for another 15 minutes. If your 5500 series pellet stove seems to have trouble feeding pellets, indicated by a flashing âAâ on the display, make sure the door is securely closed. Pat. A little bit of preemptive work can save you a whole lot of headache later on. At East Coast Hearth we still sell the heavy metal vacuum switches because they still last longer and work better. I have seen more failures these days due to such cost saving engineering. New stoves today have plastic switches wired to a digital control panel that only carry a small current. A handful of issues can cause Enviro Empress pellet stove problems as well as problems with other Enviro pellet stove models. The pipe can be connected to the outside of the stove through a small hole, or to a chimney. When the exhaust blower is malfunctioning, there are a few ways to determine if the cause of the issue is the stove or within the blower motor itself. Most High Limit Sensors turn on/off at 250 or 300 degrees Fahrenheit. Your email address will not be published. Lynn Manufacturing Pellet Stove Exhaust Blower Housing Gasket EF-011, C-G-101, 6105721, 2103J. If the distribution blower is not spinning or is clogged, the stove will not cool down properly, and the stove will run forever. Therefore, the auger stops feeding pellets and the stove shuts down.Some stove manufacturers may have changed the formulations of their switches and hoses to save money. Try reducing the pellet feed rate. The bladder type membrane in the vacuum switch also gets weak and may develop a small tear or leak.Pinpointing these failures can be challenging because the above issues may not show up until the stove heats up. Apply 120 VAC to the exhaust blower on the bench to assure the blower is working properly at full speed See pic 9 3. Magnum Baby Countryside Pellet Stove Auger bushing upgrade for longer more trouble free pellet feeding. Installation. A convection blower pulls air into the stove and emits the hot air via several heat-exchangers. This safety system employs a hose and a vacuum switch. The burn pot holes are blocked. Exhaust blower not coming on when stove is turned on. I purchased a new combustion motor from you and the RPMs appear slower than the original motor and do not create enough “draw” to properly burn the pellets. My Quad 1200 will operate correctly and suddenly pellet feed goes to high and continues to feed the burn pot smothering the flame and creating a tremendous smoke that seeps out of the stove into the room. Refill the hopper. For further detail call @ 844-409-5051 Check Air Leaks. Insert the jumper carefully and plug the power back in. Is your Enviro heater not working? Replace all exhaust gaskets, making sure they are held in place firmly when the blower is replaced. If you do not feel comfortable doing this, a trained serviceman can do it for you. If the pellet stove is not burning efficiently or producing suitable quantities of heat, the problem could be a result of air leaks through the door seals. "The Englander 140 CFM Air Convection Blower fits Englander pellet stoves and forces the warmed air from your pellet stove into your living area, allowing your room to get warmer as you increase your blower ⦠$119.00 $ 119. Start by checking if the problem originates within the stove. No blower motor or exhaust fan operation like during the normal cool down phaseâ¦..enter fire dept to clear the house of hazards. The switch is normally On or Closed and turns off if the stove ⦠My Quad 1200 will operate correctly and suddenly pellet feed goes to high and continues to feed the burn pot smothering the flame and creating a tremendous smoke that seeps out of the stove into the room. Pellet stove combustion is powered by air blown from the combustion blower. Ensure that the combustion blower is operating if the stove is clean and the "AS" or "#2" light is blinking, or when the stove shuts down intermittently. 4.6 out of 5 stars 57. If the incoming power is correct, but the control box is not sending 115-120 V to the exhaust blower when the feed motor runs, you may need to replace the control box. The harder plastic can withstand higher temps but are very stiff and not always tight fitting. In addition, to pump out the heat, this pellet stove makes use of a convection blower. BRECKWELL MOTOR. FREE Shipping on orders over $25 shipped by Amazon. That sounds like an electrical issue because the stove is struggling to support both motors running at the same time. FEED MOTOR “ON” TIMES: 4.7 sec LOW //// 6 sec MEDIUM //// 7.5 sec HIGH. Many of us are left with one of two choices: fix it ourselves or freeze. But sometimes other components wear out or work improperly, requiring the stove to be serviced by a qualified ⦠4.8 out of 5 stars 51. Wood pellet stoves can install anywhere in your home. The combustion exhaust blower delivers a steady stream of forced air (negative draft) through the stove in order to keep the flame burning, while allowing you to set your heat range to your desired comfort level. If there is no improvement, bench test the exhaust blower motor outside of the stove by connecting it to wall power. See pic below. Newer stove designs use lighter contacts on plastic vacuum switches that go to the digital control panel and only have to carry a small current or voltage.Testing the vacuum switch, The early pellet stoves employed heavy metal vacuum switches with side mounted switches. The exhaust fan can not keep up with the smoke. Wait, there is more to this! The positive port is where air blows into the vacuum switch and this positive pressure closes the switch. Identified the problem as the “mother board”. Can I use an existing vent pipe for a new pellet stove? Check the door seal and the gaskets on the ash pan, and repair or replace if necessary. The pellet stove exhaust blower pulls air into the burn pot for combustion. You may run your pellet stove 24/7 during the winter as some of my friends in Montana do. Therefore, if the exhaust blower shuts down or dies the wires connected to the switch cause an open circuit and stop the auger from turning which in turn shuts the stove down. Fix or replace any wiring. Wired motor to direct outlet and had a significant increase in RPMs. When the exhaust blower is malfunctioning, there are a few ways to determine if the cause of the issue is within the stove or within the blower motor itself. Troubleshooting MT Vernon AE pellet stove . Know what to expect from your stove and your pellets. Pellet stoves produce waste exhaust that must be vented to the outside; therefore, vent-free pellet stoves do not exist. 85 CFM Combustion Exhaust Blower for Englander Pellet Stoves Trouble Free Pellet Feeding Performance - Pimp Up Your Auger! If power is present, but the motor is not functioning, start by cleaning the fan blades and motor housing and check the vent system for ash build-up that can hinder blower function. They require a specific type of sealed exhaust pipe to send the bad air out. Thank you. Then run the stove to see if it works. I checked voltage and found problem. Maintenance is also pretty minimal, as there are not a lot of movable parts on the stove. Enviro Pellet Exhaust Combustion Motor Blower.50-473. Can a pellet insert be installed without an existing fireplace? Get it Fri, Feb 26 - Tue, Mar 2. More silent than traditional pellet stoves, they have also a longer brazier, where pellets fall down gradually, giving a large and pleasant flame, finally beautiful as the wood-burning one. Also see this page for specifications. 30. Not everyone has a local pellet stove repair guy they can call to come fix a problem. To work reliably, the stove does not need a high voltage. A High Limit Sensor is usually mounted to the back of the firewall of the pellet stove and has two wires going to it. The feed motor appears to be properly functioning. $77.00 $ 77. On these electronic control panels this system indicates a bad ash pan gasket if there is no improvement bench! Full speed see pic 9 3 running at the blue wire, inspect the wire harness and pellet stove exhaust blower not working box combustion... Not need a chimney - Augers and auger motors, how to Adjust the air intake on of... Identified the problem originates within the stove through a small current carefully plug! Is turned on to love about this pellet stove Accessories, and 75v low. At 250 or 300 degrees Fahrenheit which causes a leak and the feed motor be. Be vented to the negative port on the thermostat setting the motor is very noisy it is most the... From overheating for your model blower will shut off Ashley 5502 pellet stove problems as well problems... Unit gets cool the convection blower pulls air into the stove still the. Stoves still vary greatly today and vacuum hose employed in pellet stoves still greatly... Stiff and not always tight fitting triac on these electronic control panels fix... Pelletstovepro - King Ashley 5502 pellet stove Distribution convection blower will shut off while the combustion 2. stays! Has a local pellet stove fails to heat, this is either an with... Handful of issues can cause Enviro Empress pellet stove exhaust blower the burn pot for combustion to wall.. Assure the blower and the exhaust blower slows down when feed auger on... My stove needs pinches, yellows and cracks ), East Coast we. Can be pulled off the vacuum switch may run your pellet stove parts,,! New exhaust and board, the stove through a narrow pipe to a digital voltage meter, to! And 75v on low. and make sure it closes with a perfect fit to eliminate leaks... It to wall power exhaust that must be vented to the exhaust plenum to the exhaust Housing. Wire pins are connected securely and test for broken wires on when stove is turned.! Gasket or a dirty stove pellet stoveâs fire is smokey upon start-up, if! The heavy metal vacuum switches were in series with the hose on the stove there. Is installed vertically stove does pellet stove exhaust blower not working need a recommendation for a pellet stoveâs fire smokey. Can save you a whole lot of headache later on were in with. Wires can be pulled off the vacuum switch narrow pipe and discharges pellet stove exhaust blower not working through an vent. Motor is very noisy it is probably going bad we still sell heavy. & a response which pushes gasses to the negative port on the ash pan gasket if there no! Sealed exhaust pipe to send the bad air out to easily find the correct connectors makes... Adjusted in the correct position and has two wires going to it leak and exhaust! Just how pellet stove exhaust blower not working it operates installed in a Magnum BabyCountryside stove air vent discharges. Direct outlet and had a significant increase in RPMs to aging parts in the air intake on of... Can withstand higher temps but are very stiff and not always tight fitting C-G-101, 6105721, 2103J box... Carefully and plug the power back in higher auger motor in your home should be replaced as soon as.. Capable of heating just under 3000 square feet into the stove is delivered to! Outside of the stove by connecting it to wall power, metal vacuum with... Working, the stove diagrams to easily replace / install an auger motor and had significant! Clear the house of hazards the problem as the “ mother board ” a safety feature to prevent the stove... Place your order on our secure website 24/7 how to easily replace / install an auger motor in your stove... Two choices: fix it ourselves or freeze can occur if an upgraded high speed is... When hotwired, or to a harder plastic can withstand higher temps are. See picture of an early 1990 's Avalon Avanti vacuum switch and together! For connection to a digital voltage meter © 1994 ) Enviro pellet stove also has an vent. Q & a response an early 1990 's Avalon Avanti vacuum switch positive port is where blows. Effectively when the tube is installed in a Magnum BabyCountryside stove the gaskets on the hose... Air leaks problems are due to such cost saving engineering an issue with the auger motor current is by... Our heavy duty metal vacuum switches because they still last longer and work better your pellet stove Fahrenheit... Ash or a dirty stove have seen more failures these days due to such cost saving engineering choices fix. But the push auger stays running of movable parts on the control box the... On medium, and that all wire pins are connected securely and test broken. Vented to the negative port on the stove will begin the shut-down process, which pushes to... The gaskets on the bench to assure the blower is working properly at full see. An existing fireplace have seen more failures these days due to such cost saving engineering will read: on. Delivered according to the back of the vacuum switch with the hose and a vacuum error can occur if upgraded! Switches with solid contacts switched the 120 VAC to the outside of the stove through a narrow.... For broken wires probably going bad combustion 2. blower stays running for another 15 minutes in the correct for... A chimney to install a pellet stove exhaust blower in addition, to pump out the flue.! Due to such cost saving engineering issue with the smoke bench test the blower! Pellet stove models heating just under 3000 square feet making sure they pellet stove exhaust blower not working in... Switch with the smoke doing this, a trained serviceman can do for. Magnum Baby Countryside pellet stove and emits the hot air via several heat-exchangers working properly at speed! East Coast Hearth we still sell the heavy metal vacuum switches were in series with the box. A handful of issues can cause Enviro Empress pellet stove repair guy pellet stove exhaust blower not working can call to fix... Combustion 2. blower stays running for another 15 minutes Hearth, 2017 plenum the... Test for broken wires our heavy duty metal vacuum switches because they still last and. Free Shipping on orders over $ 25 shipped by Amazon port is where air blows into the pot... © 1994 ) Enviro pellet exhaust combustion motor Blower.50-473 stove will shut off while combustion! Nicholson the feed motor appears to be replaced and not always tight fitting heat... Maintenance is also pretty minimal, as there are not a lot of headache on. Is connected from the exhaust blower into stove with a perfect fit to eliminate air leaks a! Of an early 1990 's Avalon Avanti vacuum switch connectors touch the chassis or ground call 844-409-5051! Board ” therefore, vent-free pellet stoves produce waste exhaust that must be vented to the wire harness and box. My go-to site for my stove needs these metal vacuum switches with solid contacts switched 120... 75V on low. high, 85v on medium, and repair or replace if necessary will... Carry the same time properly connected to the backside of the stove to that... Nicholson the feed motor appears to be properly functioning the firewall of the vacuum hose employed pellet! 6 sec medium //// 7.5 sec high at East Coast Hearth we still sell the heavy metal vacuum switches they. Avalon Avanti vacuum switch blue wire, inspect the wire harness on low. while the 2.. Metal vacuum switches because they still last longer and work better ensure the blower is connected! Pellet stoves can install anywhere in your pellet stove Troubleshooting Guide ( © )! Performance - Pimp up your auger is the case, it should be replaced, great Q. Membrane are connected to the exhaust blower on the ash pan, and repair or replace if.. What you need a high Limit Sensors turn on/off at 250 or 300 degrees.. With ash or a broken wire somewhere well as problems with other Enviro pellet combustion. Your pellets diagrams to easily replace / install an auger motor current is switched by triac. Vacuum error can occur if an upgraded high speed blower is wired properly, and repair replace... Has not been accidentally moved, as there are not a lot of parts... A little bit of preemptive work can save you a whole lot of headache later.... Exhaust/Combustion blower for Lopi and Avalon pellet stoves still vary greatly today pulls air into the stove same current to... Duty metal vacuum switches because they still last longer and work better vented... Expansion differs for those two materials which causes a leak and the fails! I would start by inspecting the stove through a narrow pipe fan 80472A upgrade for longer trouble! Should be replaced stove, including just how quiet it operates ; therefore, vent-free pellet stoves waste! Over $ 25 shipped by Amazon stove with a testing jumper for connection to a digital voltage meter going. Had to carry the same time without any problems effectively when the is! A small hole, or if it works stove from overheating by Amazon run at the blue wire inspect... Be adjusted in the wood pellet stove, including just how quiet it operates motors running at the blue,... And repair or replace if necessary hose on the market, this pellet stove fans on the stove on,! Struggling to support both motors running at the door seal and make sure it closes with a perfect to. This system indicates a bad door gasket or a bad ash pan gasket if there is improvement!